Cyclone Resistant Glass Specifications
If AS/NZS 1170.2: 2002 (expired) Code is required
Cyclone Debris Impact Resistant laminated glass NATA tested and certified to AS/NZS 1170.2. – 2002, clause 5.3.2.
Thickness must comply with AS1288 Wind loads, Regions C, Design Wind Speed 70m/s.
Glasshape® StormShield® Gen 1 or equal equivalent performing certified system where framing and glass have been tested.
All glazing shall be in accordance with AS/NZS 2208: Safety Glazing Materials for use in Building & NZS4223: Code of Practice for Glazing in Building
PLEASE NOTE: If you would like to save the above Specification Code: Please highlight the above text, right click, copy and paste it into your document, OR click on the Download Specification button below.
If AS/NZS 1170.2: 2011 (current) Code is required
Cyclone Debris Impact Resistant laminated glass NATA tested and certified to AS/NZS 1170.2. – 2011, clause 2.5.8 parts A&B.
Thickness must comply with AS1288 Wind loads, Regions C, Design Wind Speed 70m/s.
Glasshape® StormShield® Gen 2 or equal equivalent performing certified system where framing and glass have been tested.
All glazing shall be in accordance with AS/NZS 2208: Safety Glazing Materials for use in Building & NZS4223: Code of Practice for Glazing in Building